Root Membrane Kit

The Golden Standard Technique for successful immediate implant placement in the esthetic zone.

Root Membrane Kit Featured Product Image | ids integrated dental systems
ids

Root Membrane Kit

The Megagen Root Membrane Kit provides the best immediate implant placement in the esthetic zone. You’ll perform the procedure faster and realize exceptional esthetic results.

Root Membrane Technique

The Root Membrane Technique is a surgical procedure performed before implant placement to induce successful osseointegration and increase the soft tissue aesthetics by minimizing the loss of the buccal bone after extraction. The procedure separates the root at the time of extraction, leaving the root partially on the buccal side. As a result, it’s possible to maintain the physiological relationship with the buccal side without deterioration.

Until now, the Root Membrane surgical procedure was performed only by highly skilled dentists. We released this kit to make the surgical procedures one that can be performed by more and more dentists. By following the step-by-step instructions, the tissue can be entirely protected with the precise tooth modification.

Root Membrane Technique | ids integrated dental systems
Within the buccal side of an immediate implant placement in the anterior maxilla, there are cementum, PDL, attachment fibers, vascularization, and bundle bone. This procedure leads to continuous and predictable osseointegration by minimizing the loss of the buccal bones caused by socket remodeling that may occur after extraction.
Root Membrane Technique Study Cover Image | ids integrated dental systems
According to a study published in JOMI, the Root Membrane Technique is an effective alternative treatment method for immediate implant placement. It has an extremely high success rate compared to implant placement after extraction. This technique has already been recognized for its effectiveness by clinicians around the globe, as well as numerous articles and case studies.

As the studies show, when the buccal root fragment is intentionally left in place, the blood supply will be maintained smoothly, and consequently the dimensions of alveolar ridge can be preserved. On the basis of this evidence, it has been established that Root Membrane Technique is a safe treatment that yields a high implant success rate.

Also, this unique technique can ensure the dimensional stability of facial and soft tissues around the implant site without supplementary biomaterials such as bone grafts. Dento-gingival fibers retained in the root fragment increase soft tissue aesthetics when they are part of an esthetical immediate implant placement.
5 Year Kaplan Meier Survival Curve Estimation Chart | ids integrated dental systems

Case Study

Fig.1 The clinical feature before surgery of the maxillary left central incisor which is planned.

Fig.2 Cone beam CT section indicates consistent loss of tooth structure with invasive cervical root resorption.

Fig. 3 Immediate implant placement on the lingual side of the root fragment.
Fig. 4 Immediate loading after fixture placement.

Fig. 5 Follow-up for 2 years, the finally restored clinical photo. (Creeping attachment)

Fig.6
Top (Left to right)
The 24-month radiograph showed a limitation of defect size, while the resorption traces of apex did not appear radially. There was no sign of radiopacity consistent with the defect fill for 36 months. Apex resorption of the root is confirmed.

Bottom (Left to right)
With 48 months of follow-up, the cross-section showed complete defect fill and about 1.5 mm root reabsorption. The reabsorption area is full of new bone cell with radiologic pattern and it leads new born growth.

Root Membrane Case Study 1 Images | ids integrated dental systems

How to Use  the Root Membrane Kit

How to Use Root Membrane Kit Step 1 | ids integrated dental systems
1. After measuring the length of root canal, secure the root canal using the Gate Glidden Drill and Bur.
How to Use Root Membrane Kit Step 2 | ids integrated dental systems
2. Use Initial Shaper (IS1) to perform an initial root split about 7mm so that lingual surface becomes slightly rounded.
3. Then use the Initial Shaper (IS2) to expand as the length of the root and remove the palatal side fragment.
How to Use Root Membrane Kit Step 3 | ids integrated dental systems
4. Use a round Diamond Drill that matches the length and size of the rootfragment. Then trim the remaining roots forming a crescent moon when viewed from the occlusal surface.

The ideal thickest central part of Root fragment is 1.5-2mm when viewed from the occlusal surface.

5. Perform the initial trimming so that the crestal part of the root fragment on the gingival part descends 3 mm below the tip of gingiva.
6. Use the Final Shaper (FS1: for low speed or FS2: for high speed) to trim and smoothen the root fragment (Crestal) remaining below the tip of the gingiva.
How to Use Root Membrane Kit Step 4 | ids integrated dental systems
7. To prevent slip of the common drill along the slot, initial drilling should be done using an initial shaper (IS2) after matching the direction in which the fixture is to be placed.
8. After that, it needs step-by-step drilling.
How to Use Root Membrane Kit Step 5 | ids integrated dental systems
9. Due to the feature of immediate placement, there is no resistance on the labial side, so labial shifting is likely to occur when the fixture is placed.

To prevent this, trim the palatal side bone before fixture placement by using tapered diamond.

It’s kind of counter sinking drilling. You can adjust the depth of the tapered diamond according to the diameter of the fixture being placed.

How to Use Root Membrane Kit Step 6 | ids integrated dental systems
10. Place the fixture without touching the remaining root fragment.

If a gap between the root fragment and the fixture is wide, perform a little bone graft.

Perfect Matching with  the AnyRidge Implant System

The advantage of the Root Membrane Technique is immediate implant placement. The most effective way to ensure a high success rate is stronger initial stability. And no implant provides better initial stability than the complete line of AnyRidge Implants. They are the perfect complement to the Root Membrane Technique.

AnyRidge Knife Thread Design

The AnyRidge Implant Knife Thread® is designed as an oblique shape that features a round face and narrow thread. You can obtain optimal ISQ because the implant is placed without damaging the unique architecture of cancellous bone. AnyRidge also provides even stress distribution.

AnyRidge XPEED Surface Treatment

XPEED® surface treatment technology includes Ca2+ions, which increases the osseointegration rate on the fixture surface. There is no problem associated with the absorption of the coating layer after scaling deterioration, and the BIC and removal torque values are excellent.
Root Membrane Kit & AnyRidge Implant System | ids integrated dental systems

The Best Diamond Drill for Root Membrane Technique

The most successful immediate implant placement in the esthetic zone is realized by combining MegaGen’s Root Membrane Kit with the best quality dental diamond drill technology from the 50-year-old Japanese company Hinatawada Precision Manufacturing.

MegaGen selected Hinatawada because it has been recognized as one of the world’s top manufacturers, and is known for is craftsman-like manufacturing philosophy. Also, Hinatawada has designed this drill to provide optimum durability, as well as the elimination of wobbling and power interruption.

Multiple Advantages

1. Eliminates excessive vibration on the teeth, achieving a smooth formed surface
2. 34mm long diamond drill does not wobble when it is used at high-speed rotation. (Rotation accuracy: less than 3 microns)
3. Sharpness of the diamond drill is extremely durable
4. The diamond drill, which is made with high precision by grinding process, displays consistent quality
5. Superior hardness of the diamond drill, eliminates the risk of bending during treatment, thus making it safer
6. A high rotation accuracy and small shaft vibration prevents abrasion of the handpiece bearing

Maximum Speed (RPM) of Drill

1,200 3DD50 SD2018L 4DD4005 SD2518L
30,000 2DD2034 2DD3034
40,000 1DD1607 1DD1911
100,000 2DD2025 2DD3025 3DD20H 2DD2029 2DD3029
Root Membrane Kit Components Ref.C RMK 3000 | ids integrated dental systems
Ref.C RMK 3000

Gate Glidden Burs*

Featured Product
Dentsply | Gate Glidden Drill
No.3 (Ø0.9) / No.4 (Ø1.1)

Shaping Drill (Gate Glidden Drills)

RPM Diameter Length(mm) Ref.C
Ø2.0 43 SD2018L
Ø2.0 43 SD2518L
Root Membrane Kit Gate Glidden Burs | ids integrated dental systems
Gate Glidden Burs
Root Membrane Kit Gate Glidden Drills | ids integrated dental systems
Gate Glidden Drills

Diamond Drill (Initial Shaper)

RPM Diameter Length(mm) Ref.C
Ø1.6 25 1DD1607 (IS1)
Ø1.9 34 1DD1911 (IS2)

Diamond Drill (Round Diamond)

RPM Diameter Length(mm) Ref.C
Ø2.0 25 2DD2025
Ø2.0 29 2DD2029
Ø2.0 34 2DD2034
Ø3.0 25 3DD3025
Ø3.0 29 3DD3029
Ø3.0 34 3DD3034
Root Membrane Kit Initial Shaper | ids integrated dental systems
Initial Shaper
Root Membrane Kit Round Diamond Shaper | ids integrated dental systems
Round Diamond

Diamond Drill (Final Shaper)

RPM Diameter Length(mm) Ref.C
Ø5.0 28 3DD50 (FS1)
Ø2.0 29 3DD20H (FS2)

Diamond Drill (Tapered Diamond)

RPM Diameter Length(mm) Ref.C
Ø4.0 32 4DD4005
Root Membrane Kit Final Shaper | ids integrated dental systems
Final Shaper
Root Membrane Kit Tapered Diamond | ids integrated dental systems
Tapered Diamond

Check Out Our Special Offers